series | FTA(Special type of kiln) |
Model | FTA99-623(FBS6-ANN-R5N-N/N/N/N) |
Size: width * height | 99(96mm*96mm) |
Thermocouple Input | K、E、J、T、B、S、Wu-3Re25、N、R |
Thermal resistance input | Pt100 |
Analog input | DC 0~5V、1~5V、0~10V、2~10V、DC4~20mA、0~20mA |
Call the police | 1 way: high alarm deviation (optional) |
output | Relay, linear voltage / current (DCmA/V), voltage pulse, thyristor trigger |
Valve feedback | With feedback: relay contact output (optional) |
Communication port | Band communication: RS485-Modbus-RTU(optional) |
Series | Size : width * height | First group of output | Second group of output | Alarm output | Valve feedback | Communication port | Input type | Power supply |
FTA (furnace special type) | 44(48*48) | N- No | N- No | N- No | N- No | N- No | D- Thermocouple | A:AC220V |
77(72*72) | R- (Relay) | R- (Relay) | 1:1 route | A:DC4-20mA | 2: RS232 communication | C- thermal resistance | D:DC24V | |
FTB (economy) | 49(48*96) | S- Solid state relay (SSR drive) | S- Solid state relay (SSR drive) | 2:2 route | B:DC0-20mA | 4:RS485 Modbus- RTU | A- Analog quantity | |
FTC (remote settings) | 94(96*48) | C:DC0-10mA | (Thermocouple and thermal resistance can be self-set by software. The analog quantity is specified when ordering) | |||||
99(96*96) | A1-4-20mA | A1-4-20mA | D:0-5VDC | |||||
FTD (heating and cooling type) | A2-0-20mA | A2-0-20mA | E:0-10VDC | E: Ethernet | ||||
VM-Three-wire proportional motor valve | V1-0-5V | F:1-5VDC | C:CAN bus | |||||
FTE (Pressure specific type) | V2-0-10V | G:2-10VDC | P:Profibus | |||||
V1-0-5V | R: potentiometer three-wire valve position feedback input | A:ASK-Link | ||||||
FTF (standard type) | V-2-0-10V | |||||||
FTP (programming type) | ||||||||
O: Other |
Instrument features
FTP: Microcomputer 32-segment program controller
Instrument selection:
参数名 | 参数值 |
series | FTA(Special type of kiln) |
Model | FTA99-623(FBS6-ABN-RSN-N/N/N/N) |
Size: width * height | 99(96mm*96mm) |
Thermocouple Input | K、E、J、T、B、S、Wu-3Re25、N、R |
Thermal resistance input | Pt100 |
Analog input | DC 0~5V、1~5V、0~10V、2~10V、DC4~20mA、0~20mA |
Call the police | 1 way: high alarm deviation (optional) |
output | Relay, linear voltage / current (DCmA/V), voltage pulse, thyristor trigger |
Valve feedback | With feedback: relay contact output (optional) |
Communication port | Band communication: RS485-Modbus-RTU(optional) |
Series | Size : width * height | First group of output | Second group of output | Alarm output | Valve feedback | Communication port | Input type | Power supply |
FTA (furnace special type) | 44(48*48) | N- No | N- No | N- No | N- No | N- No | D- Thermocouple | A:AC220V |
77(72*72) | R- (Relay) | R- (Relay) | 1:1 route | A:DC4-20mA | 2: RS232 communication | C- thermal resistance | D:DC24V | |
FTB (economy) | 49(48*96) | S- Solid state relay (SSR drive) | S- Solid state relay (SSR drive) | 2:2 route | B:DC0-20mA | 4:RS485 Modbus- RTU | A- Analog quantity | |
FTC (remote settings) | 94(96*48) | C:DC0-10mA | (Thermocouple and thermal resistance can be self-set by software. The analog quantity is specified when ordering) | |||||
99(96*96) | A1-4-20mA | A1-4-20mA | D:0-5VDC | |||||
FTD (heating and cooling type) | A2-0-20mA | A2-0-20mA | E:0-10VDC | E: Ethernet | ||||
VM-Three-wire proportional motor valve | V1-0-5V | F:1-5VDC | C:CAN bus | |||||
FTE (Pressure specific type) | V2-0-10V | G:2-10VDC | P:Profibus | |||||
V1-0-5V | R: potentiometer three-wire valve position feedback input | A:ASK-Link | ||||||
FTF (standard type) | V-2-0-10V | |||||||
FTP (programming type) | ||||||||
O: Other |